China Dc Winding Resistance Tester Price
China Dc Winding Resistance Tester Price China Dc Winding Resistance Tester Price

China Dc Winding Resistance Tester Price

Unit price settles the question only after the test current, measurement range, and calibration traceability are locked to the same revision. A 10 A bench unit with 0.05 % basic accuracy and USB

china dc winding resistance tester price - Bulk Supply and Specification Guide

Unit price settles the question only after the test current, measurement range, and calibration traceability are locked to the same revision. A 10 A bench unit with 0.05 % basic accuracy and USB logging costs differently than a 50 A portable with temperature compensation and battery operation, even when both carry the same model prefix.

Material Options and Their Trade-offs

Enclosure Class Test Lead System Cooling Method Typical Service Interval
Aluminum chassis, IP40 4-wire Kelvin clips, 3 m, 25 mm² Forced air, variable speed 24 months calibration cycle
ABS/polycarbonate, IP54 4-wire Kelvin clips, 5 m, 16 mm² Convection, no fan 12 months calibration cycle
Ruggedized aluminum, IP65 4-wire Kelvin clips, 10 m, 35 mm² Forced air, thermostatic 36 months calibration cycle

The aluminum chassis dissipates heat from the 50 A current source without fan noise, but adds 3 kg over the ABS unit. For field crews moving between substations, the IP54 convection-cooled model eliminates filter cleaning and survives rain exposure — the clips stay clean longer when stored in the molded recess. Buyers specifying the 36-month calibration interval on the ruggedized unit accept a 22 % price premium for reduced truck rolls.

Lead Resistance Compensation

Four-wire Kelvin connection removes lead resistance up to 50 mΩ per lead. At 10 A test current, 10 m of 16 mm² cable adds 11 mΩ — negligible for windings above 100 mΩ, but 11 % error on a 100 mΩ shunt. Specify 25 mm² or 35 mm² leads for low-voltage winding work.

Thermal Drift Management

Internal precision resistors track at ±5 ppm/°C. The 50 A model heats its shunt 12 °C during a 30-second test; firmware corrects using the onboard sensor. Without correction, a 0.1 Ω winding reads 0.106 Ω hot — a 6 % shift that exceeds Class 0.05 accuracy. Verify the correction algorithm version before accepting a batch.

Size, Weight and Specification Range

Before comparing quotations, align on the measurement span that covers 90 % of your transformers. A 1 μΩ–2 kΩ range with 10 A maximum current handles distribution transformers up to 10 MVA. Adding a 50 A range extends coverage to 100 MVA units but doubles the current-source cost and adds 4 kg.

Model Tier Measurement Range Test Current Accuracy (Best Range) Weight
Entry bench 1 μΩ – 2 kΩ 1 A, 10 A 0.05 % + 2 digits 4.2 kg
Mid-range portable 0.1 μΩ – 5 kΩ 1 A, 5 A, 10 A, 20 A 0.03 % + 1 digit 6.8 kg
High-current field 0.1 μΩ – 20 kΩ 1 A, 10 A, 20 A, 50 A 0.02 % + 1 digit 11.5 kg

Display resolution steps at 0.1 μΩ below 1 mΩ, 1 μΩ to 100 mΩ, and 10 μΩ above. The mid-range unit stores 10,000 readings with timestamp and winding ID; the entry model holds 500. Ethernet and Wi-Fi are factory options on the top two tiers — retrofitting requires mainboard replacement.

Quality Control and Batch Consistency

Two suppliers quoting the same specification often diverge on lot-to-lot repeatability of the current-source linearity. Our line runs a 12-point verification at 0.1 A, 1 A, 5 A, 10 A, 20 A, and 50 A against a 0.005 % standard resistor bank before each shipment. Units exceeding ±0.015 % deviation at any point are pulled for rework — typically 2–3 % of production.

china dc winding resistance tester price
Stress Parameter Test Condition Acceptance Criterion Failure Mode if Exceeded
Current source linearity 6 points, 0.1–50 A ±0.015 % of range Systematic offset on high-current ranges
Thermal coefficient 0–50 °C chamber soak ±5 ppm/°C Drift during long tests on large windings
Lead contact resistance 500 mate cycles < 5 mΩ added Erratic readings on low-voltage windings
Display/keypad life 100,000 actuations No ghost keys, contrast > 80 % Field unit becomes unusable

Each shipment includes a batch certificate listing the serial-numbered linearity plot and thermal soak result. Buyers who re-certify annually report fewer warranty returns when they archive these plots and trend the 10 A point — a 0.008 % shift over 18 months predicts calibration failure before the due date.

Stock Availability and Reorder Planning

The entry bench model ships from Shenzhen within 5 business days for orders up to 20 units. The mid-range portable carries a 15-day lead at 10 units; the high-current field unit runs 25 days due to the 50 A current-source burn-in. Blanket orders with quarterly releases lock the price and pull lead time to 7 days for all tiers.

Model Tier MOQ Standard Lead Time Blanket Order Lead Time Reorder Buffer Stock
Entry bench 1 unit 5 business days 7 business days 15 units
Mid-range portable 5 units 15 business days 7 business days 8 units
High-current field 3 units 25 business days 7 business days 4 units

Firmware updates ship on USB-C drives packed with each unit; the mid-range and high-current models support OTA via Ethernet. Specify the firmware revision at order placement — revision 3.2 added the IEEE C57.12.90 test sequence macro that saves 4 minutes per transformer.

Export Packaging and Handling Protection

Each tester ships in a double-wall corrugated carton (ECT 48) with die-cut polyethylene foam cradling the instrument and a separate compartment for the lead set. The high-current model adds a shockwatch 25 G indicator and a humidity card — units showing activation or > 60 % RH are quarantined for full re-verification before release.

  • Palletized 4 units per layer, 3 layers max, stretch-wrapped with edge protectors
  • Desiccant packs calculated at 1 unit per 0.03 m³ carton volume
  • Labeling: CE mark, WEEE symbol, serial barcode, and "Precision Instrument — Do Not Drop" in EN/ZH/ES
  • Customs HS code 9030.31 declared on commercial invoice with country of origin

Distributors re-exporting to the Middle East should request the conformal-coated PCB option — salt-fog testing shows 40 % longer creepage life on the current-source board. The coating adds 3 days to lead time and 1.8 % to unit cost but eliminates the leading cause of field returns in coastal humidity.

Serviceability Note

All three tiers use modular current-source and measurement boards replaceable with a Torx T10 driver. The entry model shares its 10 A board with the mid-range 10 A range — spares stock can be consolidated. Calibration adjustment is software-only; no potentiometers to drift. Return-to-base repair averages 6 business days plus shipping.

Ready to Specify Your Configuration?

Send your winding resistance range, test-current requirement, and annual volume. We'll return a priced BOM with lead-time options, calibration certificate format, and artwork proof for your branding — all within one business day.

Request Specification Review and Branding Proof